Leading Manufacturers, Exporters, Wholesaler, Retailer of Respirable Dust Sampler - Model No. - VRDS 500, Respirable Dust Sampler - VRDS 500DxNL, Respirable Dust Sampler VRDS 500EBL, Respirable Dust Sampler VRDS 500ENL, Respirable Dust Sampler - VRDS 500NL and Respirable Dust Sampler - VRDS-500BL from Ahmedabad.
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Respirable Dust Sampler |
Weight | 30 Kg |
Voltage | 220V |
Condition | New |
Features | Durable, Eco Friwndly, Fine Finished, Precise Design |
Warranty | ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY |
Display | Ananlog |
Flow Rate | Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter |
Automation Grade | Manual |
Brand Name | VAIBHAV |
Power | AC |
Basic features | Heavy duty brushless belt driven almost maintenance free & zero consumable blower |
Particulate Sampling | D50 cutoff cyclonic separator separate 10micron down to 0.1micron(depending upon filter). A cyclone is used for fractionating dust into two fractions. RSPM(<10μm ) are accumulate on filter paper |
Filter Holder | Fine finished power coated fabricated from aluminum casting having zero leakage / leak proof through rubber gasket at all joints to accommodate any standard filter paper of 20.3cm x 25.4cm |
Filter Media | 8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM2000 or equivalent for special monitoring / research work |
IS Reference | Match the requirement prescribed in BIS 5182(Part-23) 2006 for particulate matter collection |
Timer Recorder | 0.00 to 99999.99 hrs. time totalizer records the running time in hours |
Clock / Timer | Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time |
Sampling Time | As per user choice and upto 30 hours maximum for single operation |
Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory |
Dimension | Approximately 410mm X 300mm X 700mm |
Particle Size | Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles |
Construction | The body of RDS is robust enough to withstand impacts and vibration in transportation, it is made of heavy aluminum sheet. |
Night View | Provision has been made for light in the sampler for taking reading during dark area and in night hours |
Hardware | Only SS 304 corrosion free hardware are used in sampler for assembling |
Make | VAIBHAV EQUIPMENT SERVICE – AHMEDABAD |
Product Code | VRDS 500 |
Port | EX WORK AHMEDABAD |
Payment Terms | L/C, D/P, T/T |
Delivery Time | READY STOCK |
Preferred Buyer From
Location | Worldwide |
special features
modular design for easy operation
drain plug for manometer fluid leveling
sturdy aluminum construction with ss hardware
low noise during operations
less variation in flow even chocking of filter
maintenance free suction assembly
totally eliminated of emi
compact, portable, easy to operate-transport & handle
arrangement for parallel gaseous sampling
light provision for working in night & dark area
design to runs continuously 24 hours or more
common body (housing) structure for all the model which will easy converted to any of the below model
suitable for outdoor use, corrosion free lockable housing
.
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Respirable Dust Sampler, RESPIRABLE DUST SAMPLER |
Weight | 45 Kg |
Voltage | 220V |
Condition | New |
Features | Durable, Eco Friwndly, Fine Finished, Precise Design |
Warranty | 14 MONTHS |
Display | Digital, ANALOG (OPTIONAL) |
Flow Rate | Free flow more than 1.5 m3/min without filter paper and with flow stabilization is disable. 1.0 m3/min with filter paper installed and flow stabilization controller enabled |
Automation Grade | Fully Automatic |
Brand Name | VAIBHAV |
Power | AC |
Special Feature | Design as per Indian standard BIS 5182(Part 23):2006,digital flow indicator & volume totalizer, waterless manometer eliminate filling of distilled water & maintaining zerolevel in glass manometer tube |
Special Feature.. | Electronic flow controller, Sampling flow will maintain the pre set level even during filter chocking, ampere and voltage variation, instrument will auto shut if flow vary from set flow & time limit. |
Digital Manometer | Digital display of manometer flow on 16 character, 2 line LCD display. Flow indication in two digit with 3 decimal places & volume tantalization indication in five digit with 2 decimal place. |
Auto Zero of Volume | By pressing single key volume will be auto zero |
Particulate Sampling | 10 micron down to 0.1 micron (depending upon type of filter used). A cyclone is used for fractionating the dust into two fractions, D-50 cutoff for the cyclone is at 10 microns. |
Particulate Sampling.. | RSPM is accumulated on the filter paper (8”X10” size) while coarse dust is collected in a cup placed under the cyclone |
Filter Holder | To accommodate any standard filter paper of 20.3cm x 25.4cm (8inchX10inch) in size, particulate bigger than 10 micron collected in separate dust cap under the cyclone |
Filter Media | 8inch X 10inch (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work |
IS Reference | Match the requirement prescribed in BIS 5182(Part-23) 2006 |
Time Recorder | 0 to 99999.99 hrs. time totalizer records the running time in hours |
Clock / Timer | Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time |
Sampling Time | 30 hours (maximum) |
Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory |
Dimension | Approximately 410mm X 300mm X 700mm |
Particle Size | Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles |
Construction | The body of RDS is robust enough to withstand impacts and vibration in transportation, it is made of heavy aluminum sheet. |
Night View | Provision has been made for light in the sampler for taking reading during dark area and in night hours |
Hardware | Only SS corrosion free hardware used in sampler |
Flow Control | The system will automatically maintain the flow rate constant and compensate for dust load deposited on the filter. |
Flow Control.. | When dust load increases beyond the capacity of the blower the flow rate will begin to decrease and the system will automatically be shutdown if the flow rate tends to drop below 15% of pre set level |
Suction Blower.. | Multi bladed impeller revolves at a very high speed in a specially designed stator cum compression chamber ensuring very fine clearance between them |
Suction Blower... | The impeller is fitted directly onto a bearing mounted shaft of a superior quality flanged electric motor. 100 % oil free required zero lubrication |
Product Code | VRDS 500DxNL |
Port | AHMEDABAD |
Payment Terms | L/C, D/P, T/T |
Delivery Time | READY STOCK |
Preferred Buyer From
Location | Worldwide |
special features
confirm to bis 5182 (part 23) : 2006 standard
sampling flow rate will maintain automatic at pre set level even during filter chocking, ampere & voltage variation with electronic feedback controller
digital manometer with volume totalizing (waterless manometer, no need of filling and adjusting zero lever with distilled water)
digital manometer eliminated glass manometer tube brakeage & water evaporation during sampling
flow will be readout upto to three decimal place.
provide sample volume in at any stage of sampling on display
sturdy aluminum construction with ss hardware
little noise during operations
maintenance free brushless regenerative heavy duty induction suction assembly
totally eliminated of electromagnetic interference (emi) to tvs is totally eliminated
blower immune to voltage fluctuations thus eliminating need of voltage stabilizer
compact, portable, easy to operate-transport & handle
arrangement for parallel gaseous sampling
light provision for working in night & dark area
design to runs continuously 24 hours or more
modular design for easy operation
suitable for outdoor use, corrosion free lockable housing
.Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Respirable Dust Sampler |
Weight | 50 kg |
Voltage | 220V |
Condition | New |
Power Source | AC |
Features | Durable, Eco Friwndly, Fine Finished, Precise Design |
Warranty | ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY |
Display | Digital |
Flow Rate | Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter, |
Automation Grade | Fully Automatic |
Brand Name | VAIBHAV |
Power | AC |
Basic features | Brush less belt driven almost maintenance free & almost zero consumable blower, electronic digital manometer in place of glass manometer, digital flow indicator & volume totalizer (Digital Manometer), |
Particulate Sampling | 10micron down to 0.1micron(depending upon filter used) A cyclone is used for fractionating the dust into 2 fractions, D50 cutoff for cyclone is at 10microns. RSPM is accumulated on the filterpaper |
Filter Holder | To accommodate any standard filter paper of 25 x 20 cm, particulate bigger than 10 micron collected in separate dust cap under the cyclone |
Filter Media | 8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work |
IS Reference | Match the requirement prescribed in BIS 5182(Part-23) 2006 |
Timer Recorder | 0 to 99999.99 hrs. time totalizer records the running time in hours |
Clock / Timer | Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time |
Sampling Time | 30 hours (maximum) for single sampling |
Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory |
Dimension | Approximately 410mm X 300mm X 700mm |
Particle Size | Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles |
Construction | The body of RDS is robust enough to withstand impacts and vibration in transportation; it is made of heavy aluminum sheet. |
Night View | Provision has been made for light in the sampler for taking reading during dark area and in night hours |
Hardware | Only SS corrosion free hardware used in sampler |
Digital Display | 16 character, 2 line LED display with 5 key operation |
Product Code | VRDS 500EBL |
Port | AHMEDABAD |
Payment Terms | L/C, D/P |
Delivery Time | READY STOCK |
Preferred Buyer From
Location | Worldwide |
SPECIAL FEATURES
Digital Manometer with volume totalizing (Waterless manometer, no need of filling and adjusting zero lever with distilled water)
Provide Sample volume in m3 at any stage of sampling on display
Modular design for easy operation
Sturdy aluminum construction with SS hardware
Glass manometer tube brakeage during transportation & water evaporation is eliminated due to digital manometer
Low Noise during operations
Less variation in flow even chocking of filter
Totally eliminated of EMI
Compact, Portable, Easy to Operate-Transport & Handle
Arrangement for Parallel Gaseous sampling
Light provision for working in night & dark area
Design to runs continuously 24 hours or more
Castor provide easy internal movement
Common Body (Housing) structure for all the model which will easy converted to any of the VRDS 500series
Suitable for Outdoor Use, Corrosion free lockable housing
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Respirable Dust Sampler |
Weight | 58 Kg |
Voltage | 220V |
Condition | New |
Features | Durable, Eco Friwndly, Fine Finished, Precise Design |
Warranty | ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY |
Display | Digital |
Flow Rate | Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter |
Automation Grade | Semi Automatic |
Brand Name | VAIBHAV |
Power | AC |
Basic features | Brushless & belt less almost maintenance free & zero consumable noise less turbine blower, electronic manometer in place of glass manometer, digital flow indicator & volume totalizer, Digital Manomete |
Particulate Sampling | 10micron down to 0.1micron (depending upon filter used). A cyclone is used for fractionating the dust into 2 fractions, D50 cutoff for the cyclone is at 10microns. RSPM is accumulated on the filter |
Filter Holder | To accommodate any standard filter paper of 25 x 20 cm, particulate bigger than 10 micron collected in separate dust cap under the cyclone |
Filter Media | 8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work |
IS Reference | Match the requirement prescribed in BIS 5182(Part-23) 2006 |
Timer Recorder | 0 to 99999.99 hrs. time totalizer records the running time in hours |
Clock / Timer | Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time |
Sampling Time | 30 hours (maximum) |
Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory |
Dimension | Approximately 410mm X 300mm X 700mm |
Particle Size | Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles |
Construction | The body of RDS is robust enough to withstand impacts and vibration in transportation; it is made of heavy aluminum sheet. |
Night View | Provision has been made for light in the sampler for taking reading during dark area and in night hours and |
Hardware | Only SS corrosion free hardware used in sampler |
Product Code | VRDS 500ENL |
Payment Terms | L/C, D/P |
Delivery Time | READY STOCK |
Preferred Buyer From
Location | Worldwide |
special features
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Respirable Dust Sampler |
Weight | 30-40kg |
Voltage | 220V |
Condition | New |
Power Source | Electricity |
Features | Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design |
Warranty | 14 MONTH |
Display | Ananlog |
Flow Rate | 1-1.5m3 |
Automation Grade | Semi Automatic |
Brand Name | Vaibhav |
Power | AC Single Phase Ac Supply |
Airflow | 0.9 to 1.4 cubic meter per minute |
Dimension (L*B*H in mm) | 410 X 300 X 700 |
Production Capacity | 500 Set Per year |
Port | EX WORK AHMEDABAD |
Payment Terms | T/T |
Delivery Time | READY STOCK |
Packaging Details | Standard Packing in Hard Board with Armor Sheet Protection Having Bubble Roll Layer in Instrument |
Preferred Buyer From
Location | Worldwide |
Special Features :
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Dust Samplers, FINE PARTICULATE SAMPLER (PM 2.5 SAMPLER) |
Weight | 20-30kg |
Voltage | 220V |
Condition | New |
Power Source | 230 VAC 50 Hz |
Features | Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design |
Warranty | 14 MONTHS |
Display | Ananlog |
Flow Rate | Constant 1m3/hour (16.7 LPM) unaffected by voltage fluctuation and filter chocking through critical orifice |
Automation Grade | Manual |
Brand Name | VAIBHAV |
Usage | PM2.5 (FPM), PM10(RSPM) & Gaseous Pollutant Sampling |
Production Capacity | 200 SET FOR THE YEAR |
Weight ( in kg) | APPROXIMATE 27 KG |
Color | WHITE |
Brand | VAIBHAV EQUIPMENT SERVICE |
Material | AUMINIMUM |
Airflow | 1 M3/HSR - 16.67LPM |
Energy Consumption | SINGLE PHASE , 220V AVC, 2 AMP, |
PM 2.5 Size Separator | Two stage Impactor confirm to US EPA design, Omni directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through WINS impactor |
Filter Media | 47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly. |
Flow Meter | Dry Gas Meter record the total air volume sampler with a accuracy of 200 ML |
Clock / Timer System | Programmable Real Time control system with control of automatic start & stop of instrument |
Dimension & Weight | 300mm X 280mm X 800mm, Approximate 25 Kg |
Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory |
Operation | Up-to 28 hours continuously |
Time totalizer | 0 to 9999.99 hours recorded on a digital time totalizer |
Vacuum Pump | Oil free non pulsating pump driven by induction motor for stable flow rate |
WARRANTY | ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY |
Product Code | VRDS 500BL |
Port | EX WORK AHMEDABAD |
Payment Terms | L/C, T/T |
Delivery Time | READY STOCK |
Packaging Details | Standard Packing in hardboard box with Inner Armor Sheet Packing and Bubble Roll Layer On Instrument |
Preferred Buyer From
Location | Worldwide |
Special Features :
Hi! Simply click below and type your query.
Our experts will reply you very soon.