Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design
Warranty
14 MONTH
Display
Ananlog
Flow Rate
PM2.5 & PM10 at a constant 1m3/hr unaffected by voltage fluctuation and filter chocking through critical orifice.Gaseous Pollutant–4inlet & 1 outlet with needle valves for flow control of each unit
Automation Grade
Manual
Brand Name
VAIBHAV
Usage
AMBIENT AIR SAMPLING
Power
AC
Power Supply
220 VAC
Certificate
CALIBRATION CERTIFICATE
Color
WHITE
PM 2.5 Size Separator
Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR
PM 10 Size Separator
Single stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom.
Filter Media
47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly
Flow Meter
Independent Diaphragm gas meter for PM 2.5 & PM 10 record the total air volume sampled with a accuracy of 200 ML in each stream & acrylic body rotameter for gaseous pollutant sampling
Clock / Timer System
Programmable Real Time control system with control of automatic start & stop of instrument
Power Requirement
Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage.
Operation
Up-to 28 hours continuously
Time totalizer
0 to 9999.99 hours recorded on a digital time totalizer
sampler for simultaneous sampling of pm10 and pm2.5 particulate with single inlet
design and developed as per us epa published standard designs.
meets the requirement of pollution control board for fine dust sampling
accurate particulate sample collection of particulate
user friendly & having low operating cost
compact , portable, easy to operate & handle
arrangement for parallel gaseous sample collection
filter holders fitting in the sampler are done such so that these are remain suspended in air & thus not affected by heat of motor fitted in lower cabinet of the sampler
maintenance free suction assembly, no maintenance required
design to runs continuously more than 24 hours or more at constant flow rate of 1m3/hour, this lower rate reduce filter chocking even in area of high fpm level
suitable for outdoor use, corrosion free lockable housing for wins impactor and filter holder
filter holder is design to accept any standard 47 mm diameter filter.
oil free, brushless & less noise induction motor driven pump assembly is immune to voltage fluctuation require zero maintenance
Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR
PM 10 Size Separator
Single stage impactor matching to European Design (According to EN 12341), sample collected on standard glass micro fiber filter paper of 47mm diameter.
Filter Media
: 47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly.
Flow Rate (PM 2.5)
constant 1m3/hour unaffected by voltage fluctuation & filter chocking through critical orifice.
Flow Rate (PM 10)
constant 2.3m3/hour unaffected by voltage fluctuation and filter chocking through critical orifice
Flow Rate (GAS)
Four inlet & one outlet with needle valves for flow control of each unit through 0.3 to 3.0 LPM acrylic body rotameter
Flow Meter
Independent Diaphragm gas meter for PM2.5 & PM10 record total air volume sampled with a accuracy of 200ml in each stream to measure air sampling flowrate & acrylic body Rotameter for gaseous pollutant
Clock / Timer System
Programmable Real Time control system with control of automatic start & stop of instrument
Size, Weight & Cabinet
Size : 610 X 180 X 425 Weight : Approximate 34 Kg, Cabinet : Two Part Modular, Corrosion free, lockable and easy to transport
Power Requirement
Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage.
Operation
Up-to 28 hours continuously
Time Totalizer
0 to 9999.99 hours recorded on a digital time totalizer
Sampling Train
Four inlet and one outlet manifold with built in needle valve for flow control of each inlet. 4 Nos. of 35ml borosilicate glass Impingers for gaseous sampling
Sampling for PM10 & PM 2.5 dust are done at constant rate of 2.3m3/hr & 1m3/hr respectively, reduce filter chocking even in areas of high PM concentration
Simultaneous sampling of PM 10, PM 2.5, gaseous pollutant & heavy metals
Oil free, brushless & Less Noise diaphragm / Pistant pump assemblies are immune to voltage fluctuation & require zero maintenance.
Suitable for outdoor use with corrosion free lockable housing. Design to work in all weatehr condition
Sampler can run continuously upto 24 hours as per Guidelines.
Filter Holder is design to accept any standard 47 mm dia filter which reduce the operating cost
Compact, portable & simple to operate with user friendly features
Compact and easy to handle due to reduction in weight.
Two part of cabinet and fitment of filter holder in the sampler are such so it remain suspended in air and remain close to ambient temperature at all the time even heat of motor fitted in lower cabinet of the sampler.
Simultaneous sampling of 9 parameters like PM 10, PM 2.5, gaseous pollutant & heavy metals
Sampling for PM10 & PM 2.5 dust are done at constant rate of 1m3/hr which reduce filter chocking even in areas of high PM concentration
Two part of cabinet and fitment of filter holder in the sampler are such so it remain suspended in air and remain close to ambient temperature at all the time even heat of motor fitted in lower cabinet of the sampler.
Oil free, brushless & Less Noise Induction motor driven pump assembly is immune to voltage fluctuation & require zero maintenance.
Suitable for outdoor use with corrosion free lockable housing.
Sample can run continuously upto 24 hours or more
Filter Holder is design to accept any standard 47 mm dia filter having low operating cost
Compact, portable & simple to operate with user friendly features
Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design
Warranty
14 MONTH
Display
Ananlog
Automation Grade
Manual, Semi Automatic
Brand Name
Vaibhav
Power
220 VC AC 50 Hz
Production Capacity
100 Set Per year
Airflow
PM 2.5 - 1.0 M3/HR, PM 10 - 2.3M3/HR
Dimension (L*B*H in mm)
540 X 480 X 480
Energy Consumption
Single Phase , 220V AVC, 2 AMP,
PM 2.5 Size Separator
: Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR
PM 10 Size Separator
Single stage impactor matching to European Design (According to EN 12341), sample collected on standard glass micro fiber filter paper of 47mm diameter.
Filter Media
47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly.
Flow Rate (PM 2.5)
PM 2.5 at a constant 1m3/hour
Flow Rate (PM 10)
PM 10 at a constant 2.3m3/hour unaffected by voltage fluctuation and filter chocking through critical orifice
Flow Rate (GAS)
Gaseous Pollutant – Four inlet & one outlet with needle valves for flow control of each unit through 0.3 to 3.0 LPM acrylic body rotameter
Flow Meter
Independent Diaphragm gas meter for PM 2.5 & PM 10 record the total air volume sampled with a accuracy of 200 ML in each stream & acrylic body rotameter for gaseous pollutant sampling
Clock / Timer System
Programmable Real Time control system with control of automatic start & stop of instrument
Dimension & Weight
Dimension(mm) : LXBXH – 540X480X480 Weight : Approximate 29 Kg
Power Requirement
Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage.
Operation
Up-to 28 hours continuously
Time totalizer
0 to 9999.99 hours recorded on a digital time totalizer
Sampling Train
4 Nos. of 35ml borosilicate glass Impingers for gaseous sampling
WARRANTY
ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY
Product Code
VCDS 401
Port
EX WORK AHMEDABAD
Payment Terms
L/C, D/P, T/T, Other
Delivery Time
READY STOCK
Packaging Details
Standard Packing in Plastic Coated Hard Board with Inside Armor Sheet Protection and Bubble Roll Layer On Instrument
Simultaneous sampling of 9 parameters like PM 10, PM 2.5, gaseous pollutant & heavy metals
Oil free, brushless & Less Noise Induction motor driven pump assembly is immune to voltage fluctuation & require zero maintenance.
Sampling for PM10 & PM 2.5 dust are done at constant rate of 2.3m3/hr & 1m3/hr respectively reduce filter chocking even in areas of high PM concentration
Suitable for outdoor use with corrosion free lockable housing.
Sample can run continuously upto 24 hours as per Guidelines.
Filter Holder is design to accept any standard 47 mm dia filter which reduce the operating cost
Compact, portable & simple to operate with user friendly features
Available with NABL calibration certificate also
Folding Table will help to maintain the minimum height of inlet.
Compact and easy to handle due to reduction in weight.
Castor for easy movement and transportation
Digital Independent Filter Temperature & Ambient Temperature Indicator